Smith's (C. Shaler) formula

From StructuralWiki
Jump to: navigation, search

A formula for long timber columns:


p = \frac{5000}{1+\frac{1}{250}\frac{l^2}{d^2}}

where

p = ultimate compressive resistance in pounds per square inch

l = length of column in inches

d = least side of column section in inches